Identify the appropriate electrical intervention for the following EKG rhythms
Identify the appropriate electrical intervention for the following EKG rhythms
1.
a. Unsynchronized shock at 120-200J
b. Electrical intervention inappropriate for this rhythm
c. Synchronized cardioversion at 50 mA
d. Standby demand pacing at 60 bpm
2.
a. Defibrillation at 360 J (monophasic)
b. Deliver an asynchronous shock at 200 J (biphasic)
c. Electrical intervention inappropriate for this rhythm
d. Epicardial pacing at 100 J
3.
a. Cardioversion with 50 J
b. Unsynchronized shock at 120-200 J
c. Electrical intervention is not appropriate for this rhythm
d. Fixed rate overdrive pacing at 120 bpm
4.
a. Demand pacing at 60 bpm
b. Transcutanous pacing with 2-4J/kg
c. Defibrillation 120-200 J (biphasic)
d. Cardioversion 100 J
5.
a. Fixed rate pacing at 60 bpm
b. Electrical intervention inappropriate for this rhythm
c. Unsynchronized shock 120-200 J (biphasic)
d. Cardioversion 100 J, then 200 J for a refractory rhythm
Answers
1. d. Standby demand pacing at 60 bpm
2. c. Electrical intervention inappropriate for this rhythm
3. a. Cardioversion with 50 J
4. c. Defibrillation 120-200 J (biphasic)
5. c. Unsynchronized shock 120-200 J (biphasic)
Reviewed on 3/2/16
1.
a. Unsynchronized shock at 120-200J
b. Electrical intervention inappropriate for this rhythm
c. Synchronized cardioversion at 50 mA
d. Standby demand pacing at 60 bpm
2.
PEA rhythm |
a. Defibrillation at 360 J (monophasic)
b. Deliver an asynchronous shock at 200 J (biphasic)
c. Electrical intervention inappropriate for this rhythm
d. Epicardial pacing at 100 J
3.
a. Cardioversion with 50 J
b. Unsynchronized shock at 120-200 J
c. Electrical intervention is not appropriate for this rhythm
d. Fixed rate overdrive pacing at 120 bpm
4.
Pulseless arrest |
b. Transcutanous pacing with 2-4J/kg
c. Defibrillation 120-200 J (biphasic)
d. Cardioversion 100 J
5.
Unstable polymorphic VT |
a. Fixed rate pacing at 60 bpm
b. Electrical intervention inappropriate for this rhythm
c. Unsynchronized shock 120-200 J (biphasic)
d. Cardioversion 100 J, then 200 J for a refractory rhythm
Answers
1. d. Standby demand pacing at 60 bpm
2. c. Electrical intervention inappropriate for this rhythm
3. a. Cardioversion with 50 J
4. c. Defibrillation 120-200 J (biphasic)
5. c. Unsynchronized shock 120-200 J (biphasic)