Identify the appropriate electrical intervention for the following EKG rhythms
Identify the appropriate electrical intervention for the following EKG rhythms.
1.
a. Defibrillation 120-200 J (biphasic)
b. Defibrillation 120-200 J (monophasic)
c. Synchronized cardioversion 50 J
d. Transcutanous pacing 60 bpm (fixed)
2.
a. Defibrillation 120-200 J (biphasic)
b. Defibrillation 120-200 J (monophasic)
c. Synchronized cardioversion 50 J
d. Transcutanous pacing 60 bpm (synchronous)
3.
a. Defibrillation 120-200 J (biphasic)
b. Defibrillation 120-200 J (monophasic)
c. Synchronized cardioversion 50 J
d. Transcutanous pacing 100 ma
4.
a. Defibrillation 120-200 J (biphasic)
b. Defibrillation 120-200 J (monophasic)
c. Synchronized cardioversion 120 J
d. Transcutanous pacing 50 bpm (fixed)
5.
a. Defibrillation 120-200 J (biphasic)
b. Defibrillation 120-200 J (monophasic)
c. Synchronized cardioversion 50 J
d. Transcutanous pacing 60 bpm (demand)
Answers
1. a. Defibrillation 120-200 J (biphasic)
2. d. Transcutanous pacing 60 bpm (synchronous)
3. c. Synchronized cardioversion 50 J
4. c. Synchronized cardioversion 120 J
5. d. Transcutanous pacing 60 bpm (demand)
Reviewed on 3/2/16
1.
a. Defibrillation 120-200 J (biphasic)
b. Defibrillation 120-200 J (monophasic)
c. Synchronized cardioversion 50 J
d. Transcutanous pacing 60 bpm (fixed)
2.
a. Defibrillation 120-200 J (biphasic)
b. Defibrillation 120-200 J (monophasic)
c. Synchronized cardioversion 50 J
d. Transcutanous pacing 60 bpm (synchronous)
3.
symptomatic wide complex tachycardia |
b. Defibrillation 120-200 J (monophasic)
c. Synchronized cardioversion 50 J
d. Transcutanous pacing 100 ma
4.
a. Defibrillation 120-200 J (biphasic)
b. Defibrillation 120-200 J (monophasic)
c. Synchronized cardioversion 120 J
d. Transcutanous pacing 50 bpm (fixed)
5.
a. Defibrillation 120-200 J (biphasic)
b. Defibrillation 120-200 J (monophasic)
c. Synchronized cardioversion 50 J
d. Transcutanous pacing 60 bpm (demand)
Answers
1. a. Defibrillation 120-200 J (biphasic)
2. d. Transcutanous pacing 60 bpm (synchronous)
3. c. Synchronized cardioversion 50 J
4. c. Synchronized cardioversion 120 J
5. d. Transcutanous pacing 60 bpm (demand)
Reviewed on 3/2/16
Comments
Post a Comment